Coronary Intervention

iVascular line · distributed by XCEL

Angiolite

The DES we trust

Coronary Sirolimus-Eluting Stent — Thin-strut sirolimus DES with high overexpansion capacity for complex coronary anatomy.

Drug-eluting · Sirolimus Stent
Angiolite
Angiolite — Coronary Sirolimus-Eluting Stent
6.00 mm Overexpansion capacity*
≈75 µm Strut thickness*
44 / 49 mm Long lengths*
0.04 mm LLL at 6 mo (ANGIOLITE)*

Angiolite is a coronary sirolimus-eluting stent from iVascular, distributed by XCEL Scientific. Public product materials highlight performance in left main and bifurcation work, thin struts for small vessels, long lengths for diffuse disease, and TransferWise drug-elution technology with a fluoro-acrylate polymer intended to support early endothelialization.

*Figures summarised from iVascular public product materials. Always verify against the current IFU and local labelling.

Complex lesion readiness

Positioned for left main and bifurcation lesions with one of the highest published overexpansion capacities for large vessels (up to 6.00 mm in manufacturer materials).

Thin-strut small-vessel design

≈75 µm strut thickness adapted to small coronary arteries.

Diffuse disease lengths

Extended lengths including 44 mm and 49 mm options for long lesions.

TransferWise coating

iVascular proprietary technology for homogenous sirolimus elution; fluoro-acrylate polymer described as supporting early endothelialization.

  • Symptomatic ischemic heart disease due to de novo stenotic and restenotic lesions; occlusive disease due to acute myocardial infarction — arterial diameter 2–4.5 mm (per manufacturer labelling).
  • Clinical evidence cited by manufacturer includes ANCHOR (strut coverage), ANGIOLITE Trial (LLL), and RANGO (TLF).
Device class Coronary drug-eluting stent (sirolimus)
Material Cobalt-chromium L605, laser-cut open cell with alternating connectors
Drug Sirolimus (~1.4 μg/mm²; max load ~433 μg on largest sizes)
Coating technology TransferWise (iVascular)
Polymer Biostable fluoro-acrylate
Strut thickness ≈75 µm
Diameter range 2.00 – 4.50 mm
Length range 9 – 49 mm (44 & 49 mm long lengths)
Overexpansion 4.00 mm (Ø2.00–2.50); 5.25 mm (Ø2.75–3.50); 6.00 mm (Ø4.00–4.50)
Delivery catheter Rapid-exchange; working 142 cm / total 150 cm
Guidewire 0.014"
Distal coating Hydrophilic wear-resistant coating on distal shaft
Clinical programmes ANCHOR, ANGIOLITE Trial, RANGO Registry

Coronary DES. Long lengths 44/49 mm published for 2.50–4.00 mm diameters. Overexpansion: 4.00 mm (Ø2.00–2.50), 5.25 mm (Ø2.75–3.50), 6.00 mm (Ø4.00–4.50).

Source: iVascular / distributor technical summaries · Click ● to open the size finder.

Open available manuals below, or request a documentation pack if a file is still being prepared.

Instructions for Use (IFU) Available on request On request
Product brochure Available on request On request
Clinical summary Available on request On request
Size / ordering matrix Available on request On request